Wet Bulb Temperature Calculator

Use this Wet Bulb Temperature Calculator to estimate wet-bulb temperature from air temperature and relative humidity and understand how moisture affects evaporative cooling.

Scroll for the full guide

Wet-bulb temperature is a measure that combines ordinary air temperature with the amount of moisture in the air. It represents the temperature that can be reached through evaporative cooling under a defined set of conditions. As humidity increases, evaporation becomes less effective, and the wet-bulb temperature moves closer to the actual air temperature.

The Wet Bulb Temperature Calculator uses air temperature and relative humidity to estimate wet-bulb temperature. A commonly used approximation is the Stull (2011) formula, which expresses wet-bulb temperature as a function of temperature in degrees Celsius and relative humidity in percent. The original approximation is intended for standard atmospheric pressure and specific temperature/humidity ranges.

What Is Wet-Bulb Temperature?

Wet-bulb temperature, written as Tw, is the temperature associated with evaporative cooling of water. A traditional wet-bulb thermometer uses a wetted wick around the thermometer bulb. Moving air causes water to evaporate from the wick, cooling the thermometer. The amount of cooling depends strongly on the moisture already present in the surrounding air.

When the air is relatively dry, evaporation can occur more easily, so the wet-bulb temperature can be substantially lower than the ordinary air temperature.

When the air is very humid, evaporation is less effective. As a result, the wet-bulb temperature approaches the dry-bulb or ordinary air temperature.

At 100% relative humidity, the air is saturated and there is essentially no additional evaporative cooling under the simplified conditions represented by the wet-bulb measurement. Consequently, the wet-bulb temperature approaches the air temperature.

Wet Bulb Temperature Calculator Inputs

A typical calculator requires two primary inputs:

  • Air Temperature: The ordinary measured or observed air temperature.
  • Relative Humidity: The amount of water vapor in the air expressed as a percentage.

For the Stull approximation, temperature is entered in degrees Celsius and relative humidity is entered as a percentage such as 60 rather than 0.60. The resulting wet-bulb temperature is given in degrees Celsius.

If your starting temperature is in Fahrenheit, convert it to Celsius before applying the Stull equation:

°C = (°F − 32) × 5/9

After calculating the wet-bulb temperature in Celsius, convert the result back to Fahrenheit if needed:

°F = (°C × 9/5) + 32

Wet Bulb Temperature Formula

A widely used approximation from Stull (2011) is:

Tw = T × atan[0.151977(RH + 8.313659)1/2] + atan(T + RH) − atan(RH − 1.676331) + 0.00391838RH3/2 × atan(0.023101RH) − 4.686035

where:

  • Tw = estimated wet-bulb temperature in °C
  • T = air temperature in °C
  • RH = relative humidity in percent
  • atan = inverse tangent function

The Stull equation uses the relative humidity value as a percentage. For example, 70% humidity is entered as 70, not 0.70. The equation uses arctangent functions whose arguments are evaluated in radians.

How the Wet Bulb Temperature Calculator Works

The calculation can be understood as a sequence rather than as one large equation.

  1. Enter the air temperature.
  2. Convert the temperature to Celsius if necessary.
  3. Enter relative humidity as a percentage.
  4. Apply the wet-bulb approximation.
  5. Obtain the estimated wet-bulb temperature in Celsius.
  6. Convert the result to Fahrenheit if required.

Because the full Stull equation contains several inverse tangent terms and fractional powers, using a calculator is much less error-prone than evaluating every component manually.

Worked Example: 30°C and 60% Relative Humidity

Suppose the air temperature is:

T = 30°C

and relative humidity is:

RH = 60%

Substitute these values into the Stull approximation:

Tw = 30 × atan[0.151977(60 + 8.313659)1/2] + atan(30 + 60) − atan(60 − 1.676331) + 0.00391838(60)3/2 × atan(0.023101 × 60) − 4.686035

The resulting wet-bulb temperature is approximately 22.0°C.

Converting that value to Fahrenheit:

22.0 × 9/5 + 32 ≈ 71.6°F

So under this example’s conditions, the estimated wet-bulb temperature is approximately 22°C (71.6°F).

Example: High Humidity

Now consider warmer and more humid conditions:

Air temperature = 35°C

Relative humidity = 80%

Entering these values into the approximation gives a wet-bulb temperature of roughly 31°C.

The difference between the air temperature and wet-bulb temperature is therefore much smaller than it would be in a dry environment.

This illustrates an important relationship: high humidity reduces the amount of evaporative cooling available to the air and to a wet surface.

Example: Hot but Dry Conditions

Consider:

Air temperature = 35°C

Relative humidity = 20%

The estimated wet-bulb temperature is much lower than the actual air temperature, approximately 21°C.

The large difference occurs because relatively dry air allows much greater evaporative cooling.

These examples demonstrate why air temperature alone does not tell the complete story about the atmosphere’s moisture conditions.

Why Wet-Bulb Temperature Changes with Humidity

Evaporation requires energy. When liquid water evaporates, energy is taken from the surrounding environment, producing cooling.

Dry air can accept additional water vapor more readily than air that is already close to saturation. Therefore, evaporation can proceed more effectively in dry conditions.

Humid air has less capacity for additional water vapor. Evaporation slows, reducing the amount of cooling that can occur.

This creates the fundamental relationship behind wet-bulb temperature:

Higher humidity → less evaporative cooling → higher wet-bulb temperature.

Lower humidity → more evaporative cooling → lower wet-bulb temperature.

Wet-Bulb Temperature vs Air Temperature

Air temperature, sometimes called dry-bulb temperature, measures the temperature of the surrounding air without intentionally using evaporative cooling.

Wet-bulb temperature accounts for evaporative cooling and therefore depends on both temperature and moisture conditions.

Measurement Main Information
Dry-bulb / air temperature Ordinary air temperature
Relative humidity Amount of moisture relative to saturation
Wet-bulb temperature Temperature associated with evaporative cooling
Dew point Temperature at which air becomes saturated when cooled at constant pressure

Wet-bulb temperature is therefore not simply another way to report air temperature. It combines temperature and moisture information into a different measurement.

Wet Bulb Temperature vs Dew Point

Wet-bulb temperature and dew point are related but they are not the same measurement.

Dew point describes the temperature to which air must be cooled, at essentially constant pressure and water-vapor content, for saturation to occur.

Wet-bulb temperature is associated with evaporative cooling and depends on the thermodynamic state of the air.

Under many ordinary atmospheric conditions, the wet-bulb temperature lies between the air temperature and the dew-point temperature:

Dew point ≤ Wet-bulb temperature ≤ Air temperature

The exact relationship depends on atmospheric conditions and the definition/calculation method being used.

Wet Bulb Temperature vs Heat Index

The heat index and wet-bulb temperature are sometimes discussed together because both involve heat and humidity, but they represent different concepts.

The National Weather Service describes the heat index as a measure based primarily on air temperature and relative humidity, intended to represent how hot conditions feel in the shade.

Wet-bulb temperature, by contrast, is a thermodynamic temperature related to evaporative cooling.

Therefore, a Wet Bulb Temperature Calculator should not be treated as a Heat Index Calculator. The two values answer different questions.

Wet-Bulb Temperature vs Wet Bulb Globe Temperature

This distinction is especially important because wet-bulb temperature and Wet Bulb Globe Temperature (WBGT) are not interchangeable.

WBGT is a heat-stress indicator that incorporates multiple environmental factors. The National Weather Service gives the commonly used outdoor formulation as:

WBGT = 0.7Tw + 0.2Tg + 0.1Td

where:

  • Tw = natural wet-bulb temperature
  • Tg = globe thermometer temperature
  • Td = dry-bulb air temperature

Outdoor WBGT can also account for factors such as wind, cloud cover, solar radiation, and sun angle depending on the calculation approach.

So if you are looking for a number specifically for occupational or athletic heat-stress assessment, a WBGT Calculator is more appropriate than a basic wet-bulb temperature calculator.

Why Wet-Bulb Temperature Matters

Wet-bulb temperature is useful because it describes atmospheric moisture in a way that ordinary temperature alone cannot.

It is used in areas such as:

  • Meteorology
  • Atmospheric science
  • Weather analysis
  • Psychrometrics
  • HVAC and air-conditioning calculations
  • Evaporative cooling analysis
  • Heat and humidity studies
  • Environmental monitoring
  • Heat-stress research
  • Climate research

Researchers also use wet-bulb temperature when examining extreme heat because the combination of high temperature and high humidity can reduce the effectiveness of evaporative cooling.

Wet-Bulb Temperature and Human Cooling

The human body relies heavily on evaporation of sweat to remove heat during hot conditions. When surrounding air is humid, sweat evaporates less efficiently.

Wet-bulb temperature can therefore provide useful information about the combined effects of heat and humidity. However, it should not be interpreted as a complete measure of personal heat stress.

Actual heat stress also depends on factors such as clothing, physical activity, exposure to sunlight, wind, acclimatization, hydration, and individual characteristics.

For outdoor work or exercise, WBGT is often a more appropriate environmental heat-stress metric because it incorporates additional factors beyond air temperature and humidity.

How Accurate Is the Stull Wet-Bulb Formula?

The Stull equation is an approximation rather than a universal exact psychrometric solution.

Its major advantage is simplicity: wet-bulb temperature can be estimated from only air temperature and relative humidity without solving a full psychrometric equation.

However, the original formulation has limitations. Stull’s published equation was developed for standard pressure and a specified range of temperature and relative humidity. The paper specifically notes that the approximation is valid for a pressure of 101.325 kPa and for the combinations of temperature and humidity represented in its development data.

More sophisticated wet-bulb calculations can incorporate atmospheric pressure and use thermodynamic algorithms. Current research describes several approaches, including methods associated with Stull, Davies-Jones, and other formulations.

For ordinary educational and approximate weather calculations, the Stull equation is convenient. For specialized meteorological or engineering work, use the method appropriate to the required pressure, temperature range, and definition of wet-bulb temperature.

Can Wet-Bulb Temperature Be Higher Than Air Temperature?

For ordinary physical conditions represented by a conventional wet-bulb measurement, the wet-bulb temperature does not exceed the dry-bulb air temperature.

As relative humidity increases toward saturation, the two temperatures become closer together.

At saturation, the wet-bulb temperature approaches the air temperature.

When the air is dry, the wet-bulb temperature can be substantially lower than the air temperature because evaporation produces stronger cooling.

What Happens at 100% Relative Humidity?

At 100% relative humidity, the air is saturated with respect to water under the relevant conditions. Evaporative cooling from a wet surface is greatly limited because the surrounding air cannot readily accept additional water vapor.

Consequently, the wet-bulb temperature approaches the air temperature.

For example, if the air temperature is approximately 30°C and the relative humidity is 100%, the wet-bulb temperature is approximately 30°C under the standard assumptions of the measurement.

Wet-Bulb Temperature Conversion

If your calculator reports wet-bulb temperature in Celsius, you can convert it to Fahrenheit using:

°F = (°C × 9/5) + 32

To convert Fahrenheit back to Celsius:

°C = (°F − 32) × 5/9

For example:

25°C × 9/5 + 32 = 77°F

Therefore, a wet-bulb temperature of 25°C corresponds to 77°F.

Quick Wet-Bulb Temperature Reference

Air Temperature Relative Humidity Approximate Wet-Bulb Temperature
20°C 40% Approximately 12°C
20°C 80% Approximately 18°C
25°C 40% Approximately 17°C
25°C 80% Approximately 22°C
30°C 40% Approximately 20°C
30°C 80% Approximately 27°C
35°C 40% Approximately 25°C
35°C 80% Approximately 31°C

These values are illustrative approximations based on the Stull-style calculation and should not be treated as official weather observations or safety thresholds.

Common Mistakes When Calculating Wet-Bulb Temperature

Using Relative Humidity as a Decimal

One of the easiest mistakes is entering 0.60 when the formula expects 60%.

For the Stull equation:

60% RH → enter 60

not:

0.60

Using Fahrenheit Directly in the Stull Equation

The original Stull equation uses temperature in Celsius. Convert Fahrenheit to Celsius before applying it.

Confusing Wet-Bulb Temperature with Heat Index

They are different quantities. A wet-bulb temperature is associated with evaporative cooling, while heat index is designed to estimate perceived heat under specified assumptions.

Confusing Wet-Bulb Temperature with WBGT

WBGT includes additional environmental variables and is specifically used as a heat-stress metric. A basic wet-bulb calculation does not provide the same information.

Ignoring Atmospheric Pressure

The simple Stull approximation does not include pressure as an input and was developed for standard pressure. At significantly different elevations or pressures, a more complete psychrometric calculation may be preferable.

Wet Bulb Temperature Calculator vs Psychrometric Calculation

A simple online calculator can estimate wet-bulb temperature quickly from air temperature and relative humidity. A full psychrometric calculation is more comprehensive and may account for pressure and additional thermodynamic properties.

This distinction matters when precision is important.

Approach Typical Inputs Main Advantage
Stull approximation Temperature + RH Fast and simple
Psychrometric method Temperature + RH + pressure and other properties as needed More physically detailed
WBGT calculation Temperature, humidity, globe temperature and environmental factors Heat-stress assessment

Frequently Asked Questions

What is a Wet Bulb Temperature Calculator?

A Wet Bulb Temperature Calculator estimates the temperature associated with evaporative cooling from air temperature and relative humidity. A common approximation is the Stull equation.

What inputs are needed to calculate wet-bulb temperature?

The common simplified calculation requires air temperature and relative humidity. The Stull approximation uses temperature in Celsius and relative humidity as a percentage.

What is the wet-bulb temperature formula?

A widely used approximation is the Stull (2011) equation, which combines air temperature and relative humidity through several inverse-tangent terms and produces wet-bulb temperature in Celsius.

Is wet-bulb temperature the same as humidity?

No. Relative humidity measures how close the air is to saturation, while wet-bulb temperature combines air temperature and moisture conditions into a temperature associated with evaporative cooling.

Is wet-bulb temperature the same as heat index?

No. Heat index estimates how hot conditions feel under specific assumptions, while wet-bulb temperature is a thermodynamic measure associated with evaporative cooling.

Is wet-bulb temperature the same as WBGT?

No. WBGT is a separate heat-stress metric that incorporates wet-bulb temperature together with globe and dry-bulb temperatures and, depending on the method, environmental factors such as sunlight and wind.

What happens to wet-bulb temperature when humidity increases?

At the same air temperature, increasing relative humidity generally raises the wet-bulb temperature because evaporative cooling becomes less effective.

Can wet-bulb temperature equal air temperature?

Yes. As relative humidity approaches 100%, the wet-bulb temperature approaches the ordinary air temperature.

Why is wet-bulb temperature important in hot weather?

It provides information about the combined effects of temperature and atmospheric moisture on evaporative cooling. High humidity can make evaporation less effective, which is important when evaluating heat conditions.

Can wet-bulb temperature be calculated from dew point?

Yes, wet-bulb temperature can be determined from atmospheric thermodynamic information including temperature, dew point, and pressure. More complete meteorological calculations may use pressure and other psychrometric relationships. The National Weather Service provides calculation procedures involving temperature, dew point, relative humidity, and station pressure.

Does altitude affect wet-bulb temperature?

Yes. Atmospheric pressure changes with altitude, and pressure can affect a more complete wet-bulb calculation. The simple Stull approximation does not include pressure and was developed for standard atmospheric pressure, so it should not automatically be treated as an exact high-altitude calculation.

What is a dangerous wet-bulb temperature?

Wet-bulb temperature is sometimes discussed in relation to extreme heat and human survivability, but a single number should not be treated as a universal personal safety threshold. Heat risk depends on factors including duration, activity, sunlight, wind, clothing, acclimatization, hydration, and individual conditions. For practical outdoor heat-stress management, WBGT is often a more appropriate metric because it accounts for additional environmental factors.

Wet Bulb Temperature Calculator: Key Formulas

Purpose Formula
Fahrenheit to Celsius °C = (°F − 32) × 5/9
Celsius to Fahrenheit °F = (°C × 9/5) + 32
Stull wet-bulb approximation Tw = Stull(T, RH)
Outdoor WBGT WBGT = 0.7Tw + 0.2Tg + 0.1Td

Final Takeaway

The Wet Bulb Temperature Calculator provides a convenient way to estimate the combined effect of air temperature and relative humidity on evaporative cooling.

The most important relationship to remember is:

Higher humidity generally means a higher wet-bulb temperature at the same air temperature.

For a quick estimate, the Stull equation uses temperature in Celsius and relative humidity in percent. It is convenient for general calculations but is still an approximation with defined limitations. More advanced meteorological calculations can account for atmospheric pressure and use more comprehensive thermodynamic methods.

Finally, do not confuse wet-bulb temperature with heat index or Wet Bulb Globe Temperature. These measurements overlap in the study of hot and humid conditions but are designed for different purposes. WBGT is particularly relevant when evaluating heat stress during outdoor work or exercise because it incorporates additional environmental conditions beyond temperature and humidity.

References

  • Stull, R. — Wet-Bulb Temperature from Relative Humidity and Air Temperature, Journal of Applied Meteorology and Climatology.
  • American Meteorological Society — discussion of simplified wet-bulb approximations and Stull’s method.
  • National Weather Service — Wet Bulb Globe Temperature and comparison with Heat Index.
  • National Weather Service — Wet-Bulb Temperature and Dewpoint Temperature from Air Temperature and Relative Humidity.